Skip to content
DustHazardAnalysis.ca
Menu

Combustible Dust Guides

Short, plain-language guides to the questions that come before and after a dust hazard analysis.

Estimate your cost

Would you like to get pricing for the following equipment that will likely be required as a result of your study?

These combustible dust guides answer the questions that come up before and after a dust hazard analysis: whether a dust counts at all, what NFPA's consolidated standard means for a Canadian plant, and when the analysis has to be done again. Each one is short, written in plain language, and built on the regulations, codes and NFPA material it names.

Which combustible dust guides are there?

There are three combustible dust guides so far, and the table gives what each covers, the rules or standards it is built on, and a link to it.

Combustible dust guides: what each covers and what it is built on
GuideWhat it coversBuilt on
Is my dust combustible?A 6-question checklist from whether a process makes dust to whether to test it or assume it is combustible.BC OHS 6.134, 6.137–6.139; WHMIS criteria
NFPA 660 in CanadaWhat the 2025 consolidation changed, and where Canadian codes still cite the older NFPA standards.NFPA 660 publisher summary; fire codes
DHA revalidationWhen a dust hazard analysis is due again, what brings it forward, and what the revalidation checks.NFPA 652 five-year review; BC OHS 6.140 (3)

What comes after the guides?

After the guides come the studies themselves: a dust that turns out to be combustible needs a dust hazard analysis or, in British Columbia, a combustion risk assessment, and a DHA that is due again needs an update.

The dust hazard analysis page describes the study, the combustible dust testing page the laboratory tests, and the cost listing every starting range. Industry by industry, the combustible dust industries page shows where each dust is found.

The editorial standards behind every guide are on the about page, questions go by email to the address on the contact us page, and the privacy policy and terms cover your use of the site.

Questions about the guides

Which guide should I read first?

Read the "Is my dust combustible?" guide first if you are not sure your dust is a hazard; it ends in a test-or-assume decision. It follows BC’s identification sections 6.137 to 6.139 and the WHMIS Combustible Dusts criteria.

Are these guides legal advice?

These guides are not legal advice; they explain what the named regulations, codes and standards say. Each guide names its sources in the text and lists them at the end, and an engineer confirms how they apply to your plant.

Do the guides cover Quebec?

The guides do not cover Quebec, which this site leaves out; they apply to every other province and territory. The rules they cite come from BC, Alberta, Saskatchewan, Manitoba, Ontario, New Brunswick and the National Fire Code of Canada 2020.

Do I need a DHA once I know my dust is combustible?

Once you know your dust is combustible, you need some form of dust hazard analysis wherever it is made, handled or collected. In British Columbia that is the combustion risk assessment under section 6.140 from January 4, 2027, and elsewhere the national fire code’s dust section applies to buildings where combustible dusts create a hazard.

Sources

  1. Approved amendments for Part 6, Combustible Dusts, in the Occupational Health and Safety Regulation and the Prevention Manual (opens in a new tab), WorkSafeBC.
  2. Hazardous Products Regulations (SOR/2015-17), Subpart 17 Combustible Dusts and Schedule 5 (opens in a new tab), Government of Canada, Justice Laws.
  3. NFPA 660, Standard for Combustible Dusts and Particulate Solids (opens in a new tab), National Fire Protection Association.
  4. NFPA 652, Combustible Dust Awareness and Hazard Evaluation (online training series) (opens in a new tab), National Fire Protection Association.