Skip to content
DustHazardAnalysis.ca
Menu

Dust Hazard Analysis in New Brunswick

New Brunswick's dust collector rule, WorkSafeNB's guidance on combustible dust, and the Fire Marshal's technical note.

Estimate your cost

Would you like to get pricing for the following equipment that will likely be required as a result of your study?

A dust hazard analysis in New Brunswick has a specific rule to work from: since April 1, 2024, a dust collector of more than 0.6 cubic metres that controls combustible dust has to be located and built so that an explosion inside it endangers no one. WorkSafeNB treats explosive wood dust as an undue hazard, and the Fire Marshal's office has published a 24-item technical note on dust-producing processes. A DHA brings those together for your plant, collector by collector and room by room.

Who needs a dust hazard analysis in New Brunswick?

New Brunswick employers running a dust collector over 0.6 m³ for combustible dust, or any operation where dust could build up near an ignition source, are the clearest cases for a DHA, because the regulation and WorkSafeNB's guidance both target those conditions.

WorkSafeNB's safety talk on combustible dust says that under the Occupational Health and Safety Act no one may carry out work that would create an undue hazard, and that "Wood dust is considered an undue hazard if it creates the potential for an explosion or if it can be inhaled by the employees." General Regulation 91-191 adds the collector rule and general dust duties. The regulation itself never mentions a dust hazard analysis; a DHA is the study that shows how a plant meets those duties.

What does General Regulation 91-191 require for combustible dust?

For combustible dust, New Brunswick's General Regulation 91-191 sets a collector rule, a general duty to control dust levels, and limits on equipment and hot work near explosive dust.

  • Section 24 (2.71). On or after April 1, 2024, a dust collector with an internal volume greater than 0.6 m³ used to control combustible dusts is located and constructed so that no employee is endangered by an explosion inside it. The wording applies to every such collector from that date, not only to collectors installed after it.
  • Section 25.2. Where dust may create a hazard to employees' health or safety, the employer controls the dust level so it does not endanger them.
  • Section 216 (2) (a). An industrial lift truck with an internal combustion engine is not operated near areas containing explosive dusts.
  • Section 262.013 (1). Equipment used in a confined space that may contain flammable dust is intrinsically safe.
  • Section 275 (1). Welding, cutting, burning or soldering starts only after the surrounding area has been inspected and combustible, flammable or explosive material, including dust, removed or guarded against.

Does New Brunswick's dust collector rule apply to my collector?

New Brunswick's dust collector rule applies to any collector with an internal volume over 0.6 m³ that controls combustible dust, and the fire code adds its own outdoor rule for collectors above 2.36 m³/s.

Does the dust collector rule apply to you? 4 questions

  1. Is the dust collector used to control combustible dusts?Yes: Go to question 2.No: Section 24 (2.71) does not apply to it; section 25.2 still requires dust levels to be controlled where dust may endanger employees.
  2. Is its internal volume greater than 0.6 m³?Yes: Go to question 3.No: Section 24 (2.71) does not apply to that collector, but the fire code and section 25.2 can.
  3. Is the collector located and constructed so that no employee would be endangered by an explosion inside it?Yes: That is what section 24 (2.71) has required since April 1, 2024.No: The employer has had to ensure it since April 1, 2024; an engineer can say how, for example by location, venting or containment.
  4. Is the collector’s capacity greater than 2.36 m³/s?Yes: Under Article 5.3.1.4 of the National Fire Code of Canada 2020, in force in New Brunswick since May 1, 2025, it goes outside with explosion venting, or inside only with venting to the outdoors, an automatic explosion prevention system or a fire-separated room.No: Article 5.3.1.4 does not apply, but the rest of Section 5.3 of the fire code still covers dust removal, bonding and venting.

The sections are in General Regulation 91-191 under the Occupational Health and Safety Act and in the National Fire Code of Canada 2020. The engineer confirms the answers for your collector.

What does the fire code require in New Brunswick?

As of November 2026, New Brunswick applies the National Fire Code of Canada 2020, adopted through the Fire Prevention and Inspection Regulation from May 1, 2025, and the Fire Marshal's technical note on dust-producing processes explains how it applies to dust collection.

Technical Note 2019-01 says the national code "contains the guidance for designing, installing and maintaining dust collection equipment and dust removal", that dust-collecting systems must be designed to good engineering practice, and that the code relies on NFPA standards to help engineers with those designs: NFPA 68, 69, 77, 91, 654 and 664. It lists 24 key items, each tied to a fire code article, for industry to review, and the national articles behind them are summarized on the combustible dust fire code page.

Who enforces combustible dust rules in New Brunswick?

Combustible dust in New Brunswick workplaces comes under occupational health and safety officers appointed by the Workplace Health, Safety and Compensation Commission, who can give orders under the Act, while the Office of the Fire Marshal is responsible for fire safety inspections and building plan reviews.

In Bathurst, Dieppe, Edmundston, Fredericton, Miramichi, Moncton, New Maryland, Oromocto, Riverview and Saint John, building inspections fall to the local fire department; elsewhere, a Provincial Fire Prevention Officer. A request for a DHA can follow either kind of inspection, or come from a property insurer's own conditions.

How does a DHA differ from meeting the collector rule?

Meeting New Brunswick's collector rule settles one piece of equipment, while a DHA covers every process, duct, collector and room where combustible dust is made or moved, and the fire, flash fire and explosion scenarios at each.

Section 24 (2.71) sets an outcome for collectors over 0.6 m³ without saying how to reach it. A DHA, as NFPA 652 describes it, evaluates the hazards around the collector and across the plant and recommends safeguards with an implementation plan, which can include the answer for the collector.

What does a dust hazard analysis cost in New Brunswick, and how long does it take?

Starting at $8,000–$15,000 before HST for one process or dust collection system, a New Brunswick dust hazard analysis typically finishes within 4–8 weeks of the go-ahead, and a dust that still has to be sent for laboratory testing pushes that out by 3–6 weeks.

Plants with several processes take longer, and this page's estimator opens on New Brunswick and a dust hazard analysis.

Which New Brunswick operations do these rules point to?

New Brunswick's rules point first to wood dust and to any plant with a dust collector over 0.6 m³, since WorkSafeNB's safety talk is written around wood dust and the regulation's collector rule covers every combustible dust.

The Fire Marshal's technical note includes NFPA 664, the wood processing and woodworking standard, alongside the general standard for combustible particulate solids, NFPA 654.

New Brunswick combustible dust questions

Does New Brunswick have a dust collector rule?

New Brunswick has a dust collector rule: since April 1, 2024, a collector over 0.6 m³ for combustible dust must not endanger employees if an explosion occurs inside it. Section 24 (2.71) of General Regulation 91-191 under the Occupational Health and Safety Act sets that requirement.

Can a worker refuse work near built-up wood dust in New Brunswick?

A New Brunswick worker can refuse work that presents an undue hazard, and WorkSafeNB treats wood dust as an undue hazard where it could explode or be inhaled. WorkSafeNB’s combustible dust safety talk explains that right under the Occupational Health and Safety Act, and section 24 of the Act protects workers from discriminatory action for using it.

What does the Fire Marshal’s technical note on dust cover?

The New Brunswick Fire Marshal’s technical note on dust-producing processes lists 24 key items for industry to review against the National Fire Code of Canada and the related NFPA standards. Technical Note 2019-01 (March 2019) names NFPA 68, 69, 77, 91, 654 and 664 as the standards the code relies on for design.

How often should a New Brunswick DHA be updated?

A New Brunswick DHA should be revisited at least every five years under NFPA 652 and whenever a collector, process or dust changes. Any collector over 0.6 m³ that controls combustible dusts has had to meet section 24 (2.71) of General Regulation 91-191 since April 1, 2024, whatever its installation date.

What happens if hot work starts before the area is checked?

Hot work may not start in New Brunswick until the surrounding area has been inspected for combustible, flammable or explosive material, including dust. Section 275 (1) of General Regulation 91-191 requires that inspection, and removal of the material or adequate precautions against fire or explosion, before welding, cutting, burning or soldering begins.

Sources

  1. General Regulation 91-191 under the Occupational Health and Safety Act (opens in a new tab), Government of New Brunswick.
  2. Occupational Health and Safety Act (O-0.2), sections 5 and 31 (opens in a new tab), Government of New Brunswick.
  3. Safety Talk: Combustible Dust (opens in a new tab), WorkSafeNB.
  4. Bulletin 2025-01: 2020 National Model Code adoption and regulatory updates (opens in a new tab), Office of the Fire Marshal, New Brunswick.
  5. Fire inspections, plans and standards (opens in a new tab), Government of New Brunswick.
  6. Technical Note 2019-01: Dust-Producing Processes (opens in a new tab), Office of the Fire Marshal, New Brunswick.
  7. National Fire Code of Canada 2020 (opens in a new tab), National Research Council Canada.
  8. NFPA 652, Combustible Dust Awareness and Hazard Evaluation (online training series) (opens in a new tab), National Fire Protection Association.